Supports all VME modules supported by Series 90-70.
Supports RX7i data monitoring over the web. Allows a combined total of up to 16 web server
and FTP connections.
INQUIRE NOW
Products Name: A05B-2255-C101EGN GE Input module Brand new
PRODUCT DESCRIPTION
Brand:GE
Model number: A05B-2255-C101EGN
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.27kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
A05B-2255-C101EGN GE Input module Brand new
Multiple calls to SVC_REQ 57 in a single
sweep may cause CPU watchdog timeouts
Multiple calls to SVC_REQ 57 (Logic Driven Write to Nonvolatile
Storage) could result in the CPU tripping the watchdog timer and going
to STOP-HALT mode. The number of calls to SVC_REQ 57 that can
be made requires consideration of many variables, what the software
watchdog timeout value is, how much data is being written, how long
the sweep is, age of nonvolatile storage (flash), etc. If the application
attempts to write to flash too frequently, the CPU could experience a
watchdog timeout while waiting for a preceding write operation to
complete.
The Logic Driven Read/Write to Flash service requests are not
intended for high frequency use. GE Intelligent Platforms recommends
limiting the number of calls to SVC_REQ 57 to one call per sweep to
avoid the potential of for causing a watchdog timeout and the resulting
transition to Stop-Halt.
Error response 1 is no longer returned
for Modbus RTU requests with invalid
or undefined function code
Prior to Release 6.71 for the RX7i, the Modbus RTU slave protocol
would return an Invalid Function Code error response (1) upon receipt
of a request with an invalid or undefined function code. Starting with
Rel 6.71, the Modbus RTU slave ignores requests with an invalid or
undefined function code, and no response is sent.
Block name now provided in User
Application faults
In previous firmware versions, the fault entry for a non-fatal application
fault (for example, reference-out-of-range) provided numeric
information to identify the logic block causing the error. However, the
user did not have a way to correlate the numeric information with the
name of the block. The new firmware includes the first 12 characters
of the block name in the fault entry.
CPE010, CPE020, CRE020 indicates
Stop/Fault during Winload
Between the CPU and Ethernet portions of a firmware update on a
CPE010, CPE020, or CRE020 Winloader will issue a “CPU STATE
MISMATCH” dialog and prompt to place the CPU in Stop/No IO (IO
Disabled) mode. To remedy this, click “Yes” to continue the upgrade.
Undefined symbols in C Blocks In Release 5.00 or later, if an attempt is made to download a C block
containing undefined symbols, the download will fail. Machine Edition
will display the following message in the Feedback Zone: Error 8097:
Controller Error – Controller aborted the request [0x05][0xFF]
Prior to Release 5.00, C blocks containing undefined symbols could be
successfully downloaded, but if they were executed the CPU would
transition to Stop/Halt mode
Discrete Input
Modules(1) IC200MDL140 Input 120 VAC (1 Group of 8) 8
Points IC200MDL631 Input 125 VDC Pos/Neg Logic
Isolated 8 Points
IC200MDL141 Input 240 VAC (1 Group of 8) 8
Points IC200MDL632 Input 125 VDC Pos/Neg Logic
Isolated 16 Points
IC200MDL143 Input 120 VAC Isolated 8 Points IC200MDL635 Input 48 VDC Pos/Neg Logic (2
Groups of 8) 16 Points
IC200MDL144 Input 240 VAC Isolated 4 Points IC200MDL636 Input 48 VDC Pos/Neg Logic (4
Groups of 8) 32 Points
IC200MDL240 Input 120 VAC (2 Groups of 8) 16
Points IC200MDL640 Input 24 VDC Pos/Neg Logic (2
Groups of 8) 16 Points
IC200MDL241 Input 240 VAC (2 Groups of 8) 16
Points IC200MDL643 Input 5/12 VDC Pos/Neg Logic (2
Groups of 8) 16 Points
IC200MDL243 Input 120 VAC Isolated 16 Points IC200MDL644 Input 5/12 VDC Pos/Neg Logic (4
Groups of 8) 32 Points
IC200MDL244 Input 240 VAC Isolated 8 Points IC200MDL650 Input 24 VDC Pos/Neg Logic (4
Groups of 8) 32 Points